Page view 5
6 GLND-SVX01B-EN
Model Number Descriptions
Indoor Gas Heating
Units
Note: All units are AGA approved. For
CGA approved units, contact Air
Handling Product Support.
Digit 1 — Gas Heating
Equipment
G = Gas Heating Equipment
Digit 2 — Product Type
L = High Efficiency Indoor Duct
Furnace
Digit 3 — Fuel
N= Natural Gas
P=LP Gas (Propane)
Digit 4 — Development
Sequence
D = Fourth Generation
Digits 5, 6, 7 — Input Capacity
Single Furnace
Digit 8 — Main Power Supply
Digit 9 — Gas Control Option
D = Single-Stage, Intermittent Pilot
Ignition
E = Two-Stage, Intermittent Pilot
Ignition
H = Electronic Modulating with
Room
T-Stat, Intermittent Pilot Ignition
J = Electronic Modulating with
Duct-Stat, Intermittent Pilot
Ignition
L = Electronic Modulating with
External 4–20 mA Input
N = Electronic Modulating with
External 0–10 Vdc Input
T = Single Stage Direct Spark
Ignition
V = Two-Stage, Direct Spark Ignition
Digit 10 — Design Sequence
G = Seventh Design
Digit 11 — Heat Exchanger
Material
1 = Aluminized Steel
3 = #321 Stainless Steel
Digit 12 — Rooftop
Arrangements
0 = None (Indoor Unit)
Digit 13 — Rooftop Heating Unit
Motor Selection
0 = None (Indoor Unit and Rooftop
Duct Furnace)
Digit 14 — Rooftop Fan Section
0 = None (Indoor Unit and Rooftop
Duct Furnace)
Digit 15 — Miscellaneous
Options
0=None
A = #409 Stainless Steel Burners
B = Orifices For Elevation Above
2000 Feet (Specify Elevation)
C = #409 Stainless Steel Draft
Diverter
D = Summer-Winter Switch
F = Horizontal Louvers
G = Horizontal and Vertical Louvers
K = Side Access Burner Drawer (Left
Hand)
1
L = Fan Time Delay Control
M = Side Access Burner Drawer
(Right Hand)
1
Horizontal Blower
Assembly
Digit 1, 2, 3 — Horizontal
Blower Assembly
Digit 4 — Development
Sequence
C = Third Generation
Digit 5, 6 — Blower Size
15 = Nominal 1500 cfm
20 = Nominal 2000 cfm
30 = Nominal 3000 cfm
45 = Nominal 4500 cfm
Digit 7 — Transition Size
(Specifies Duct Furnace Size)
Digit 8 — Main Power Supply
Digit 9 — Motor Horsepower
Digit 10 — Design Sequence
D = Fourth Design
Digit 11 — Miscellaneous
Options
0=None
1 = Insulation
3 = Totally Enclosed Motor
003 = 30 MBh 015 = 150 MBh
004 = 45 MBh 017 = 175 MBh
006 = 60 MBh 020 = 200 MBh
007 = 75 MBh 022 = 225 MBh
009 = 90 MBh 025 = 250 MBh
010 = 100 MBh 030 = 300 MBh
012 = 125 MBh 035 = 350 MBh
040 = 400 MBh
A = 115/60/1 D = 230/60/3
B = 230/60/1 E = 460/60/3
C = 208/60/3 F = 575/60/3
1
The left or right hand side of the side access burn-
er drawer, options K & M, is determined by facing
the air outlet side of the duct furnace.
0 = None
A = 100 MBh F = 225 MBh
B = 125 MBh G = 250 MBh
C = 150 MBh H = 300 MBh
D = 175 MBh J = 350 MBh
E=200 MBh K=400 MBh
A = 115/60/1 D = 230/60/3
B = 230/60/1 E = 460/60/3
C = 208/60/3
A = 1/3 hp D = 1 hp
B = 1/2 hp E = 1-1/2 hp
C = 3/4 hp F = 2 hp