SAFETY WARNING
Only qualified personnel should install and service the equipment. The installation, starting up, and
servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific
knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could
result in death or serious injury. When working on the equipment, observe all precautions in the literature
and on the tags, stickers, and labels that are attached to the equipment.
Gas Unit Heater
Separated Combustion Indoor Gas-Fired Duct Furnace
March 2012 GMND-SVX01B-EN
Installation, Operation,
and Maintenance
Page view 0
1 2 3 4 5 6 ... 40 41

Summary of Contents

Page 1 - Installation, Operation

SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating,

Page 2 - Environmental Concerns!

10 GMND-SVX01B-ENUnit Dimensions and WeightsTable 1. Specification data: Separated Combustion Duct FurnaceUnit SizeA B C D (Dia.)(a)Gas Inletin. Weigh

Page 3 - Trademarks

Unit Dimensions and WeightsGMND-SVX01B-EN 11 Table 2. Performance data Unit SizeInputOutput MIN Temp. Rise P.D. MAX Temp. Rise P.D.MAX MINMBh (kW) MB

Page 4 - Introduction

12 GMND-SVX01B-ENInstallation: MechanicalNote: Furnace sizing should be based on heat loss calculations where the furnace output equals or exceeds hea

Page 5 - Table of Contents

Installation: MechanicalGMND-SVX01B-EN 13 Increasing the clearance distances may be necessary if there is a possibility of distortion or discoloration

Page 6 - Model Number Descriptions

Installation: Mechanical14 GMND-SVX01B-ENbypass around the gas duct furnace to bypass a portion of the air.SuspensionNozzle AssemblyUse the following

Page 7 - General Information

Installation: MechanicalGMND-SVX01B-EN 15 is facing the unit heater, attach the top panel (P/N 251-07942-00X) to the top bracket and the two (2) side

Page 8 - Identification of Parts

16 GMND-SVX01B-ENInstallation: PipingGas PipingPipe SizingTo provide adequate gas pressure to the gas duct furnace, size the gas piping as follows:1.

Page 9

Installation: PipingGMND-SVX01B-EN 17 Pipe Installation1. Install the gas piping in accordance with applicable local codes.2. Check gas supply pressur

Page 10 - Unit Dimensions and Weights

Installation: Piping18 GMND-SVX01B-ENPipe directly in to combination valve (see Figure 8, p. 18).5. A 1/8 in. N.P.T. plugged tapping, accessible for

Page 11

Installation: PipingGMND-SVX01B-EN 19 1. The combustion air system installation must be in accordance with the latest edition of (N.F.P.A. 54) ANSI Z2

Page 12 - Installation: Mechanical

© 2012 Trane All rights reserved GMND-SVX01B-ENWarnings, Cautions and NoticesWarnings, Cautions and Notices. Note that warnings, cautions and noti

Page 13 - NOTICE:

Installation: Piping20 GMND-SVX01B-EN4. Any run of single wall vent pipe passing through an unheated space must be insulated with an insulation suita

Page 14

Installation: PipingGMND-SVX01B-EN 21 Installation: Concentric Vent Te r m i n a lHorizontal TerminationSelect a location on an outside wall for the v

Page 15

Installation: Piping22 GMND-SVX01B-ENThe location of the vent terminal must be in accordance with the National Fuel Gas Code ANSI Z223.1 in the U.S.

Page 16 - Installation: Piping

Installation: PipingGMND-SVX01B-EN 23 Cut a hole through the roof for an 8-inch combustion air pipe. Fasten a length of 5-inch pipe to the exhaust con

Page 17 - Pipe Installation

24 GMND-SVX01B-ENInstallation: ElectricalElectrical ConnectionsStandard units are shipped for use on 115 volt, 60 hertz single phase electric power. T

Page 18 - Installation: Venting

Installation: ElectricalGMND-SVX01B-EN 25 firing. This setpoint should be measured for the best results. Use the recommended ranges as a guide. If fur

Page 19

26 GMND-SVX01B-ENStart-UpOperationExplanation of Controls1. Each Separated Combustion Duct Furnace comes equipped with a power vent system that consis

Page 20

Start-UpGMND-SVX01B-EN 27 Figure 18. Burner components (intermittent pilot ignition)Burner Drawer Common Parts: 1. Main Burners 2. Burner Manifold 3.

Page 21 - Te r m i n a l

Start-Up28 GMND-SVX01B-ENGas Input RateCheck the gas input rate as follows:1. Turn off all gas appliances that utilize gas through the same gas meter

Page 22 - Vertical Termination

Start-UpGMND-SVX01B-EN 29 Pilot Adjustment1. Remove the pilot adjustment cap.2. Adjust the pilot screw to provide a properly sized flame.3. A proper p

Page 23

Warnings, Cautions and NoticesGMND-SVX01B-EN 3 TrademarksTrane and the Trane logo are trademarks of Trane in the United States and other countries. A

Page 24 - Installation: Electrical

Start-Up30 GMND-SVX01B-ENGas Equipment Start-Up Customer _____________________________________________ Job Name & Number ______________________

Page 25 - Fan Time Delay Control

GMND-SVX01B-EN 31 MaintenancePeriodic ServiceAll Maintenance/Service information should be recorded accordingly on the inspection sheet provided in th

Page 26 - Start-Up

Maintenance32 GMND-SVX01B-EN Figure 20. Power venter assemblyNotes: 1. For item No. 6, use counter-clockwise rotation. 2. DO NOT OVERTIGHTEN CELCON N

Page 27

MaintenanceGMND-SVX01B-EN 33 Installation Instructions for Field Replacement of Power Venter MotorImportant: This replacement must be performed only b

Page 28 - Overfiring!

Maintenance34 GMND-SVX01B-ENHow to Order Replacement PartsPlease send the following information to your local Parts center; If further assistance is

Page 29 - Manifold Pressure Adjustment

GMND-SVX01B-EN 35 DiagnosticsTroubleshootingWARNINGHazardous Service Procedures!The maintenance and troubleshooting procedures recommended in this sec

Page 30 - Gas Equipment Start-Up

Diagnostics36 GMND-SVX01B-ENF. Gas Odor. 1. Shut off gas immediately! 1. Inspect all gas piping and repair.2. Blocked heat exchanger/venting. 2. Clea

Page 31 - Maintenance

DiagnosticsGMND-SVX01B-EN 37 2. Pilot adjustment screw turned too low on combination main gas valve.2. Increase size of pilot flame. Refer to “Operati

Page 32

Diagnostics38 GMND-SVX01B-ENU. No Spark. 1. Thermostat not calling for heat. 1. Close thermostat contacts.2. No low voltage. 2. Check for 24V across

Page 33 - Tools and Parts Needed

GMND-SVX01B-EN 39 Wiring DiagramsFigure 22. Standard wiring diagram for unit with S8600 ignition system

Page 34

4 GMND-SVX01B-ENIntroductionFor Your SafetyThe use and storage of gasoline or other flammable vapors and liquids in open containers in the vicinity of

Page 35 - Diagnostics

Wiring Diagrams40 GMND-SVX01B-ENFigure 23. Standard wiring diagram for unit with G770 ignition system

Page 36

Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, com

Page 37

Table of ContentsGMND-SVX01B-EN 5Warnings, Cautions and Notices . . . . . . . . . . 2Model Number Descriptions . . . . . . . . . . . . . . 6Indoor

Page 38

6 GMND-SVX01B-ENModel Number DescriptionsIndoor Gas Heating UnitsNote: All units are AGA approved. For CGA approved units, contact Air Handling Produ

Page 39 - Wiring Diagrams

GMND-SVX01B-EN 7 General InformationDescriptionThe duct furnace design is certified by ETL for use with natural and LP (propane) gases. ANSI and NFPA

Page 40

General Information8 GMND-SVX01B-ENground, the grounding means must be tested by a qualified electrician.• Do not insert fingers or foreign objects i

Page 41

General InformationGMND-SVX01B-EN 9 Figure 2. Internal furnace assembly 1. Flue Collector2. Heat Exchanger3. Burner Drawer123