Trane Modular 20 to 35 Tons Installation Manual

Browse online or download Installation Manual for Unknown Trane Modular 20 to 35 Tons. Trane Modular 20 to 35 Tons Installation and Maintenance Manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SAFETY WARNING
Only qualified personnel should install and service the equipment. The installation, starting up, and
servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific
knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could
result in death or serious injury. When working on the equipment, observe all precautions in the literature
and on the tags, stickers, and labels that are attached to the equipment.
Air Cooled Condenser
20-60Ton
February 2013 CXRC-SVX01F-EN
Installation, Operation,
and Maintenance
Models
CCRC020 CCRC025 CCRC030
CCRC035 CCRC040 CCRC050
CCRC060
CIRC020 CIRC025 CIRC030
CIRC035 CIRC040 CIRC050
CIRC060
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - Installation, Operation

SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, andservicing of heating, ventilating,

Page 2 - Environmental Concerns!

Dimensions and Weights10 CXRC-SVX01F-ENService ClearancesProvide sufficient clearance around the unit to allowunrestricted access to control panel, co

Page 3 - Introduction

Dimensions and WeightsCXRC-SVX01F-EN 11Figure 6. Top view CCRC/CIRC 20, 29, 32Figure 7. Top view CCRC/CIRC 35, 40ABCD96” (2132 mm)48”(1066 mm)96” (213

Page 4 - Table of Contents

Dimensions and Weights12 CXRC-SVX01F-ENFigure 11. Typical side-by-side installation recommended clearances. All unit sizes.Service Clearance35-40T Uni

Page 5 - Model Number Descriptions

CXRC-SVX01F-EN 13Installation - MechanicalUnit Handling ProcedureLifting brackets are provided along the base rail on bothsides of the unit. Pass lift

Page 6 - General Data

Installation - Mechanical14 CXRC-SVX01F-ENInstallation PreparationBefore installing the unit, perform the followingprocedures to ensure proper unit op

Page 7

Installation - MechanicalCXRC-SVX01F-EN 15Leveling the UnitBefore tightening down the mounting bolts, level the unitcarefully. Use the unit base rail

Page 8 - Pre-Installation

Installation - Mechanical16 CXRC-SVX01F-ENRefrigerant Piping RecommendationIsolate refrigerant lines from the building to preventtransferring line vib

Page 9

CXRC-SVX01F-EN 17Installation - ElectricalGeneral Electrical RecommendationsAll wiring and disconnects must comply with local andNational Electrical C

Page 10 - Service Clearances

Installation - Electrical18 CXRC-SVX01F-ENExample:L1 measured = 221 VL2 measured = 230 VL3 measured = 227 VNote: L1 = 221 volts is the maximum deviati

Page 11 - Dimensions and Weights

CXRC-SVX01F-EN 19Operating PrincipalsControl Sequences of Operation for Unitswith IntelliPak™Typical Unit OperationSequence of operation will be descr

Page 12

© 2013Trane All rights reserved CXRC-SVX01F-ENWarnings, Cautions and NoticesWarnings, Cautions and Notices. Note that warnings,cautions and notices ap

Page 13 - Installation - Mechanical

20 CXRC-SVX01F-ENPre-Start ChecklistAfter the unit is installed, complete each step in thechecklist that follows and check off each step as completed.

Page 14 - Unit Isolation

CXRC-SVX01F-EN 21Start-Up and ShutdownStart-UpWhen wired properly, the unit will cycle condenser fans inresponse to compressor interlock or the Intell

Page 15 - Refrigerant Piping

22 CXRC-SVX01F-ENMaintenanceBefore beginning any maintenance procedures heed allwarnings and cautions.Refrigerant SystemRefrigerant Leak Test Procedur

Page 16 - Interconnecting Piping

MaintenanceCXRC-SVX01F-EN 23discharge line access port). Add refrigerant to reachpressure of 12 to 15 psig.4. Disconnect refrigerant cylinder. Connect

Page 17 - Installation - Electrical

Maintenance24 CXRC-SVX01F-ENrise.The maximum allowable rise over a 15 minute periodis 200 microns. If the pressure rise is greater than 200microns but

Page 18

MaintenanceCXRC-SVX01F-EN 25and Table 2, p. 7. Calculate additional charge required forany other units and additional piping to determine the totalsys

Page 19 - Operating Principals

Maintenance26 CXRC-SVX01F-ENaddition, use a quality detergent; like SPREX AC, OAKITE161 or OAKITE 166 and COILOX.Note: If detergent is strongly alkali

Page 20 - Pre-Start Checklist

CXRC-SVX01F-EN 27Wiring DiagramsNote: Published unit wiring diagrams are available via e-library.Drawing Number Description2313-1633 Schematic; Power

Page 21 - Start-Up and Shutdown

Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, theleader in creating and sustaining safe, comf

Page 22 - Maintenance

Warnings, Cautions and NoticesCXRC-SVX01F-EN 3IntroductionAbout This ManualNote: One copy of this document ships inside the controlpanel of each unit

Page 23 - Motor Winding Damage!

4 CXRC-SVX01F-ENTable of ContentsModel Number Descriptions ... 5General Data ... 6Unit Description ...

Page 24 - Compressor Damage!

CXRC-SVX01F-EN 5Model Number DescriptionsDigit 1 - Unit ModelC = CondenserDigit 2 - Unit TypeC = CommercialI = IndustrialDigit 3 - Condenser MediumR =

Page 25 - Hazardous Chemicals!

6 CXRC-SVX01F-ENGeneral DataUnit DescriptionModel CCRC/CIRC units function as the outdoor condenserunit for appropriately sized split refrigeration sy

Page 26 - Troubleshooting

General DataCXRC-SVX01F-EN 7Table 1. SCRF/SIRF Air–cooled self–contained and CCRC/CIRC remote air-cooled condenser, refrigerant dataSCRF/SIRF & CC

Page 27 - Wiring Diagrams

8 CXRC-SVX01F-ENPre-InstallationReceivingReceiving ChecklistComplete following checklist immediately after receivingshipment to detect any shipping da

Page 28

CXRC-SVX01F-EN 9Dimensions and WeightsFigure 2. CCRC/CIRC 20, 29, and 32(Optional) LowAmbient Damper(One damper percircuit)Refrigerant LineConnections

Comments to this Manuals

No comments