Trane Indirect Fired Make-Up Air Parts List

Browse online or download Parts List for Unknown Trane Indirect Fired Make-Up Air. Trane Indirect Fired Make-Up Air Catalogue User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Heating, Cooling, Ventilating

MUA-DS-5January 1998Second PrintingOutdoor GasHeating Units andDuct FurnacesPackaged Rooftop Unit forHeating, Cooling, Ventilatingand Make-Up Air Appl

Page 2 - Benefits

10Table G-1  Filter DataRooftop Unit SizeArrangement 10,15 20,25,50 30,35,60,70 40,80,12B-E (4)16 x 20 (4)20 x 20 (4)16 x 20 (6)20 x 20(2)20 x 20G-L

Page 3 - Contents

100WeightsTable W-1  Gravity Vented Unit and Option Weight Data (Pounds)A B C D E G J K L OutsideArrangement Net Ship Net Ship Net Ship Net Ship Net

Page 4 - Configurations

101WeightsTable W-4  Motor WeightsVoltage 1/2 HP 3/4 HP 1 HP 1 1/2 HP 2 HP 3 HP 5 HP 7 1/2 HP 10 HP 15 HP115/60/1 ODP 20 25 25 40 42 80 NA NA NA NA

Page 5

102Options ThermostatsSingle-Stage Room Thermostat(Order No. 134-0207-01)Low Voltage (24V)40 F to 90 F RangeFan Auto-On SwitchSystem Heat-Off-Cool

Page 6

103Electronic Modulating DuctThermostat(Included with Gas Control)Low voltage (24 V)55-90 F rangeSensor: 10-inch probeRemote temperature selector:

Page 7 - Description

104OptionsControlsElectronic Modulating4-20 mA or 0-10 VDC InputA200 signal conditionerControl replaces amplifier in duct orroom control packageDi

Page 8

105FeaturesSummaryTrane rooftop gas heating units havethe following design features: All units have AGA and CGA certifiedduct furnaces.ETL and CSA U

Page 9

106MechanicalSpecificationsRooftopDuct FurnaceArrangement AGENERALUnits shall be completely factoryassembled, piped, wired and test fired.All duct fur

Page 10 - Table G-1  Filter Data

107MechanicalSpecificationsFACTORY INSTALLED OPTIONSControl Options (Per Furnace) Two-Stage Gas ValveProvides two stages of heat. Ignition isat low fi

Page 11 - Considerations

108MechanicalSpecificationsFirestatIf temperature reaches the setpoint, theunit will close all gas valves, return thedampers to their normal position

Page 12

109MechanicalSpecificationsArrangement B, C, D, EGENERALUnits shall be completely factoryassembled, piped, wired and test fired.All units shall contai

Page 13

11Gas Heating ValueThe majority of gas heating units areinstalled in applications where naturalgas is readily available. In areas wherenatural gas is

Page 14

110MechanicalSpecificationsFACTORY INSTALLED OPTIONSControl Options (Per Furnace) Two-Stage Gas ValveProvides two stages of heat. Ignition isat low fi

Page 15

111MechanicalSpecifications Single-Speed TEFC60 HZ/1800 RPMSingle-Phase (with contactor) Optional 115V, 208V and 230V motorsavailable in 1/2 - 1 1/2

Page 16

112MechanicalSpecifications OA/RA Modulating Motor withSpace Pressure ControllerModulating motor with spring returnand interlocked outside and return

Page 17

113MechanicalSpecifications Continuous Fan Relay  24V CoilDPDT 10ARelay provided with 24 volt coil anddouble pole double throw 10 ampcontacts. Plugs

Page 18

114MechanicalSpecificationsRooftopHeating UnitArrangement G, J, K, LGENERALUnits shall be completely factoryassembled, piped, wired and test fired.All

Page 19 - Procedure

115MechanicalSpecificationsFACTORY INSTALLED OPTIONSControl Options (Per Furnace) Two-Stage Gas ValveProvides two stages of heat. Ignition isat low fi

Page 20

116Motors  GeneralAll motors shall be ball bearing typewith resilient base mount and NEMAframe sizes from 48 to 256T. Windingsare Class B, 1800 rpm

Page 21

117MechanicalSpecifications OA/RA Mod Mtr W/Dry Bulb/MixedAir Control/Min Pot/Spring ReturnModulating motor with interlockedoutside and return air dam

Page 22

118MechanicalSpecifications Interlock Relay  24/115V Coil SPDT10ARelay has a selectable coil voltage of 24or 115-volts and single pole doublethrow 10

Page 24

12Careful review of the job applicationwith respect to use, probablecontaminants within a conditionedspace and the amount of fresh air to bebrought in

Page 25

Library Product LiteratureProduct Section Air HandlingProduct Make-Up AirModel 000Literature Type Data Sales CatalogSequence 5Date January 1998File No

Page 26 - Adjustment

13ApplicationConsiderationsGeneral System TypesSingle-Zone Staged SystemsElectronic controls generally providemore stages of control with a higherdegr

Page 27

14ApplicationConsiderationsMultizone Staged SystemsMultizone staged systems act on thesame basic principals as a single-zonestaged system where as eac

Page 28

15ApplicationConsiderationsRooftop Make-Up Air Unit with aRooftop Exhaust UnitOutside air is introduced in order toreplace or make up for exhausted ai

Page 29

16ApplicationConsiderationsThe basic direct digital control (DDC)system uses a microprocessor basedcontroller and software to performsystem and buildi

Page 30

17ApplicationConsiderationsVentingThe venting is an integral part of thefurnace and must not be altered in thefield. The rooftop furnaces areequipped

Page 31

18ApplicationConsiderationsHigh Pressure Regulators Natural Gas OnlyThe Trane gas heating productscontained in this catalog are designedto operate at

Page 32

19SelectionProcedureQuick Sizer Chart 1Furnace Type (A, B) Standard Temperature RiseRooftop Arrangement (B, C, D, E)

Page 33

2©American Standard Inc. 1998FeaturesandBenefitsThe Trane rooftop line is a packaged airheating and cooling system, suitablefor heating, cooling, vent

Page 34

20SelectionProcedureQuick Sizer Chart 2Furnace Type (C, D) High Temperature RiseRooftop Arrangement (B, C, D, E)

Page 35

21SelectionProcedureQuick Sizer Chart 3Furnace Type (A, B) Low Temperature RiseRooftop Arrangement (G, J, K, L)

Page 36

22SelectionProcedureQuick Sizer Chart 4Furnace Type (C, D) High Temperature RiseRooftop Arrangement (G, J, K, L)

Page 37

23SelectionProcedureStep 1To properly select a unit, two of thethree following items must be known:temperature rise (TR) required, cubicfeet per minut

Page 38

24SelectionProcedureTable SP-1  Air Changes Per MinuteZoneType Heat Load 1 2 3 4High Load/High Gain 3/4 11 1/3 2High Load/Normal Gain 1/2 3/4 11 1

Page 39

25Table SP-2  Enthalpy of Saturated Air atVarious Wet BulbTemperatures Wet BTU Wet BTU Bulb per Bulb PerTemp. Pound Temp. Pound50 20.38 65 30.0550.5

Page 40

26Table PAF-1  Correction Factors for AltitudeAltitude (Feet)0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000Temp. Barometri

Page 41

27Chart PD-1  Duct Furnace PerformanceFurnace Type  (A, B)PerformanceDataStandard Temperature Rise Duct Furnace PerformanceFurnace Type  (A, B)20-6

Page 42 - Electrical

28PerformanceDataTable PD-2  Rooftop Gas Heating Units Performance Data  Furnace Type (A,B) Standard Temperature Rise  Rooftop Arrangement B,C,D,EC

Page 43

29PerformanceDataTable PD-3  Rooftop Gas Heating Units Performance Data  Furnace Type C,D  High Temperature Rise  Rooftop Arrangement B,C,D,ECapac

Page 44

3Features and Benefits 2Unit Configurations 4Model Number Description 7General Data 9Application Considerations 11Selection Procedure 20Performance Ad

Page 45

30PerformanceDataTable PD-4  Rooftop Gas Heating Units Accessory Pressure Loss Data  Rooftop Arrangements B,C,D,EPressure Loss (Inches of Water)Rain

Page 46 - Dimensional

31PerformanceDataTable PD-4 (Continued)  Rooftop Gas Heating Units Accessory Pressure Loss Data  Rooftop Arrangements B,C,D,EPressure Loss (Inches o

Page 47

32PerformanceDataTable PD-5  Rooftop Gas Heating Units Performance Data - Furnace Type (A,B) - Standard Temperature Rise - Rooftop Arrangement G,JCap

Page 48

33PerformanceDataTable PD-6  Rooftop Gas Heating Units Performance Data - Furnace Type (A,B) - Standard Temperature Rise - Rooftop Arrangement K,LCap

Page 49

34PerformanceDataTable PD-8  Rooftop Gas Heating Units Accessory Pressure Loss Data  Rooftop Arrangement G,J,K,LPressure Loss (Inches of Water)Rainh

Page 50

35PerformanceDataTable PD-8 (Continued)  Rooftop Gas Heating Units Accessory Pressure Loss Data  Rooftop Arrangement G,J,K,LPressure Loss (Inches of

Page 51

36PerformanceDataTable PD-9  DX Cooling Coil Performance Data (Ref. R-22)  Rooftop Arrangements K, LCapacity based on 95 F EDB, 74 F EWB, 45 F Sat.

Page 52

37PerformanceDataTable PD-10  DX Cooling Coil Performance Data (Ref. R-22)  Rooftop Arrangements K, LCapacity based on 80 F EDB, 67 F EWB, 45 F Sat.

Page 53

38PerformanceDataTable PD-11  Standard Conditions and Specifications  Refrigerant DX CoilCONDITIONSElevation 0 Ft.Entering Air Temperature DB: 80 F

Page 54

39PerformanceDataTable PD-12  Chilled Water Coil Performance Data  Rooftop Arrangements K, LCapacity based on 95 F EDB, 74 F EWB, 45 EWT, 70 GPMNumb

Page 55

4Unit Type Standard FeaturesArrangement A - Natural or LP (Propane Gas)Rooftop Duct Furnace - Single Stage 24-Volt Gas Valve- Intermittent Pilot Ignit

Page 56

40Table PD-13  Chilled Water Coil Performance Data  Rooftop Arrangements K, LCapacity based on 80 F EDB, 67 F EWB, 45 EWT, 70 GPMNumber of RowsAir F

Page 57

41PerformanceDataTable PD-14  Standard Conditions and Specifications  Chilled Water CoilCONDITIONSElevation 0 Ft.Entering Air Temperature DB: 80 F

Page 58

42ElectricalDataRooftop Gas Heating Units  Motor Electrical DataVoltage 1/2 HP 3/4 HP 1 HP 1 1/2 HP 2 HP 3 HP 5 HP 7 1/2 HP 10 HP 15 HP115/60/1 ODP

Page 59

43ControlsOutside Air or Return AirTwo-Position Motor/Spring ReturnUnits with outside air or return air onlyshall be provided with damper, two-positio

Page 60

44ControlsOutside Air/Return Air ModulatingMotor W/Space Pressure ControllerModulating motor with spring returnand interlocked outside and return aird

Page 61

45ControlsSingle-Stage ControlOutdoor gas heating units are providedwith an automatic single-stage gasvalve as standard. This valve is an on/off type

Page 62

46DimensionalDataRooftop Gas Duct Furnace  Arrangement ASingle Furnace 10-40 (100-400 MBh)POWER VENT (MODELS 10-40)(Left Hand Service Access Shown)NA

Page 63

47DimensionalDataUnit Dimensional Data  Rooftop Gas Duct Furnace  Arrangement AD Gas InletCapacity A B C AGA CGA *F K NAT LP10 32 7/8 15 9/16 12 11

Page 64

48DimensionalDataRooftop Gas Duct Furnace  Arrangement ADouble Furnace 50-80 (500-800 MBh)Standard (40-120°) Temperature Rise FurnaceNATURAL VENT (MO

Page 65

49Unit Dimensional Data  Rooftop Gas Duct Furnace  Arrangement AD Gas InletCapacity A B C AGA CGA *F K NAT LP50 43 7/8 29 5/16 23 1/2 16 25 3/16 34

Page 66

5UnitConfigurationsUnit Type Standard FeaturesArrangement D Same as Arrangement B with:Rooftop Heating Unit with Standard Blower - Evaporative Cooler

Page 67

50DimensionalDataRooftop Gas Duct Furnace  Arrangement ATriple Furnace 12 (1200 MBh)Standard (40-120°) Temperature Rise FurnaceNATURAL VENT (MODEL 12

Page 68

51Unit Dimensional Data  Rooftop Gas Duct Furnace  Arrangement AD Gas InletCapacity A B C AGA CGA *F K NAT LP12 60 3/845 13/1626 17 1/226 11/1651 57

Page 69

52DIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS ARE IN MILLIMETERS.DimensionalDataStandard Blower Module for Arrangements B, C, D, EUnit Sizes 10

Page 70

53DIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS ARE IN MILLIMETERS.DimensionalDataHIGH CFM BLOWER MODULE*For Cooling Arrangements Only(Left Hand

Page 71

54Air Intake HoodArrangements B, C, D, E, G, J, K, LUnit Sizes 10-12 (100-1200 MBh)DimensionalDataDIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS A

Page 72

55Over/Under Air Intake with HoodArrangements B, C, D, E, G, J, K, LUnit Sizes 10-12 (100-1200 MBh)DimensionalDataDIMENSIONS ARE IN INCHES, DIMENSIONS

Page 73

56DimensionalDataOver/Under Air Intake without HoodArrangements B, C, D, E, G, J, K, LUnit Sizes 10-12 (100-1200 MBh)DIMENSIONS ARE IN INCHES, DIMENSI

Page 74

57DimensionalDataDIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS ARE IN MILLIMETERS.Supply Plenum ModuleArrangements C, E, J, LUnit Sizes 10-12 (10

Page 75

58DimensionalDataDIMENSIONS ARE IN INCHES, DIMENSIONSIN PARENTHESIS ARE IN MILLIMETERS.Coil ModuleArrangements K, LUnit Sizes 10-80 (100-800 MBh)L I

Page 76

59DimensionalDataDIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS ARE IN MILLIMETERS.Evaporative Cooler ModuleArrangements D, EUnit Sizes 10-80 (100

Page 77

6Unit Type Standard FeaturesArrangement K Same as Arrangement G with:Rooftop Heating Unit with High Cfm Blower - Coil Sectionand Coil Cabinet - Mounti

Page 78

60DimensionalDataDIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS ARE IN MILLIMETERS.ARRANGEMENT BMODELS 10-40NATURAL VENT(Left Hand Service Acces

Page 79

61Unit Dimensional Data  Arrangement B 10-40 (100-400 MBh)A.G.A. C.G.A. GAS INLETCAPACITY A B C D D *F G J NAT LP10 32 7/8 15 9/16 12 11 20 11/16 19

Page 80

62DimensionalDataDIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS ARE IN MILLIMETERS.Rooftop Heating Unit with Standard Blower  Arrangement BModels

Page 81

63Unit Dimensional Data  Arrangement B  50-80 (500-800 MBh)A.G.A. C.G.A. GAS INLETCAPACITY A B C D D *F G J NAT LP50 43 7/8 29 5/16 23 1/2 16 25 3/1

Page 82

64DimensionalDataDIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS ARE IN MILLIMETERS.Rooftop Heating Unit with Standard Blower and Downflow Supply P

Page 83

65DimensionalDataPower Vent ModelUnit Dimensional Data  Arrangement C  10-40 (100-400 MBh)A.G.A. C.G.A. GAS INLETCAPACITY A B C D D *F G J NAT LP10

Page 84

66DimensionalDataDIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS ARE IN MILLIMETERS.Rooftop Heating Unit with Standard Blower and Downflow Supply P

Page 85

67DimensionalDataUnit Dimensional Data  Arrangement C  50-80 (500-800 MBh)A.G.A. C.G.A. GAS INLETCAPACITY A B C D D *F G J NAT LP50 43 7/8 29 5/16 2

Page 86

68DimensionalDataDIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS ARE IN MILLIMETERS.Rooftop Heating Unit with Standard Blower and Evaporative Coole

Page 87

69DimensionalDataUnit Dimensional Data  Arrangement D  10-40 (100-400 MBh)A.G.A. C.G.A. GAS INLETCAPACITY A B C D D *F G J NAT LP10 32 7/8 15 9/16 1

Page 88

7ModelNumberDescriptionDigit 1  Gas Heating EquipmentG = GasDigit 2  Unit TypeF = Rooftop Duct FurnaceR = Rooftop Heating UnitS = Special Unit TypeD

Page 89

70DIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS ARE IN MILLIMETERS.DimensionalDataRooftop Heating Unit with Standard Blower and Evaporative Coole

Page 90

71Unit Dimensional Data  Arrangement D  50-80 (500-800 MBh)A.G.A. C.G.A. GAS INLETCAPACITY A B C D D *F G J NAT LP50 43 7/8 29 5/16 23 1/2 16 25 3/1

Page 91

72Rooftop Heating Unit with Standard Blower, Evaporative Coolerand Downflow Supply Plenum  Arrangement EModels GRAA, GRBA, GRCA, GRDA  10, 15, 20, 2

Page 92

73Unit Dimensional Data  Arrangement E  10-40 (100-400 MBh)A.G.A. C.G.A. GAS INLETCAPACITY A B C D D *F G J NAT LP10 32 7/8 15 9/16 12 11 20 11/16 1

Page 93

74DIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS ARE IN MILLIMETERS.DimensionalDataRooftop Heating Unit with Standard Blower, Evaporative Cooleran

Page 94

75Unit Dimensional Data  Arrangement E  50-80 (500-800 MBh)A.G.A. C.G.A. GAS INLETCAPACITY A B C D D *F G J NAT LP50 43 7/8 29 5/16 23 1/2 16 25 3/1

Page 95

76DIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS ARE IN MILLIMETERS.DimensionalDataRooftop Heating Unit with High Cfm Blower  Arrangement GModels

Page 96

77DimensionalDataUnit Dimensional Data  Arrangement G  20-40 (200-400 MBh)A.G.A. C.G.A. GAS INLETCAPACITY A B C D D *F G J NAT LP20 43 7/8 23 13/16

Page 97

78DIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS ARE IN MILLIMETERS.DimensionalDataRooftop Heating Unit with High Cfm Blower  Arrangement GModels

Page 98

79Unit Dimensional Data  Arrangement G  50-80 (500-800 MBh)A.G.A. C.G.A. GAS INLETCAPACITY A B C D D *F G J NAT LP50 43 7/8 29 5/16 23 1/2 16 25 3/1

Page 99

8ModelNumberDescriptionDigit 18  Air Inlet Configuration0 = None (Rooftop Duct Furnace)1 = Outside Air (OA) (Horizontal Inlet)2 = Outside Air W/Air H

Page 100 - Table W-3  Roof Curb Weights

80DIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS ARE IN MILLIMETERS.DimensionalDataRooftop Heating Unit with High Cfm Blower  Arrangement GModels

Page 101 - Table W-4  Motor Weights

81DimensionalDataUnit Dimensional Data  Arrangement G  12 (1200 MBh)A.G.A. C.G.A. GAS INLETCAPACITY A B C D D *F G J NAT LP12 60 3/8 45 13/16 26 17

Page 102 - Options Thermostats

82DIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS ARE IN MILLIMETERS.DimensionalDataRooftop Heating Unit with High Cfm Blower and Downflow Supply P

Page 103 - Controls

83DimensionalDataUnit Dimensional Data  Arrangement J  20-40 (200-400 MBh)A.G.A. C.G.A. GAS INLETCAPACITY A B C D D *F G J NAT LP20 43 7/8 23 13/16

Page 104 - Roof Curbs

84DIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS ARE IN MILLIMETERS.DimensionalDataRooftop Heating Unit with High Cfm Blower and Downflow Supply P

Page 105 - Features

85DimensionalDataUnit Dimensional Data  Arrangement J  50-80 (500-800 MBh)A.G.A. C.G.A. GAS INLETCAPACITY A B C D D *F G J NAT LP50 43 7/8 29 5/16 2

Page 106 - Duct Furnace

86DIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS ARE IN MILLIMETERS.DimensionalDataARRANGEMENT JMODEL 12NATURAL VENT(Left Hand Service Access Sh

Page 107

87DimensionalDataUnit Dimensional Data  Arrangement J  12 (1200 MBh)A.G.A. C.G.A. GAS INLETCAPACITY A B C D D *F G J NAT LP12 60 3/8 45 13/16 26 17

Page 108

88DIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS ARE IN MILLIMETERS.DimensionalDataRooftop Heating Unit with High Cfm Blower and Coil Cabinet  Ar

Page 109 - Heating Unit

89Unit Dimensional Data  Arrangement K  10-40A.G.A. C.G.A. GAS INLETCAPACITY A B C D D *F G J NAT LP10 32 7/8 15 9/16 12 11 20 11/16 19 3/8 31 1/16

Page 110

9Furnace Type A,B Capacity 50-80 Capacity 50-80 Capacity 50-80 Capacity 50-80∆T40 - 120F 50 - 3,000-3,500 CFM, 1 - 5 HP 50 - 3,000-3,500 CFM, 1 - 5 HP

Page 111

90Rooftop Heating Unit with High Cfm Blower and Coil Cabinet  Arrangement KModels GRAA, GRBA  50, 60, 70, 80 (500-800 MBh)Double FurnaceStandard (40

Page 112

91DimensionalDataUnit Dimensional Data  Arrangement K  50-80 (500-800 MBh)A.G.A. C.G.A. GAS INLETCAPACITY A B C D D *F G J NAT LP50 43 7/8 29 5/16 2

Page 113

92DIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS ARE IN MILLIMETERS.DimensionalDataARRANGEMENT LMODELS 10-40NATURAL VENT(Left Hand Service Acces

Page 114

93DimensionalDataUnit Dimensional Data  Arrangement L  10-40 (100-400 MBh)A.G.A. C.G.A. GAS INLETCAPACITY A B C D D *F G J NAT LP10 32 7/8 15 9/16 1

Page 115

94Rooftop Heating Unit with High Cfm Blower, Coil Cabinetand Downflow Supply Plenum  Arrangement LModels GRAA, GRBA  50, 60, 70, 80 (500-800 MBh)Dou

Page 116

95DimensionalDataUnit Dimensional Data  Arrangement L  50-80 (500-800 MBh)A.G.A. C.G.A. GAS INLETCAPACITY A B C D D *F G J NAT LP50 43 7/8 29 5/16 2

Page 117

96DIMENSIONS ARE IN INCHES, DIMENSIONS INPARENTHESIS ARE IN MILLIMETERS.DimensionalDataRooftop Gas Heating Unit  Arrangements B-LRoof Curb10, 15, 20,

Page 118

97DimensionalDataRoof OpeningModel D E10,15 24 26(610) (660)20,25,50 35 37(889) (940)30,35,60,70 46 48(1168) (1219)40,80,12 51 1/2 53 1/2(1308

Page 119

98DimensionalDataCurb SpecificationsCapacity Dimension E*10/15 26 (660)20/25/50 37 (940)30/35/60/70 48 (1219)40/80/12 53 1/2 (1359*All dimensions

Page 120

99DimensionalDataUnit/Curb End Rail AssemblyCurb Cap End Adaptor -Supplied with the Unit(one each end)Unit/Base Rail AssemblyRooftop Gas Heating Units