Trane Unit Ventilator Energy Recovery System Parts List

Browse online or download Parts List for Unknown Trane Unit Ventilator Energy Recovery System. Trane Unit Ventilator Energy Recovery System Catalogue User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - UV-PRC005-ENMarch 2006

UV-PRC005-ENMarch 2006Classroom Unit Ventilator AccessoriesAccessories from A to ZWall Boxes, Energy Recovery System, Shelving, Side Wall Exhaust, Gra

Page 2 - Introduction

10 UV-PRC005-ENDIGIT 13: END COVERS0 = No End CoversA = 16 5/8-inch Deep End Covers w/o CutoutsB = 16 5/8-inch Deep End Covers w/Std. CutoutsC = 16 5/

Page 3 - Contents

UV-PRC005-EN 11Model NumberEnergy Recover Unit VentilatorDIGIT 1-3: UNIT CONFIGURATIONERS = Energy Recovery SystemDIGIT 4: DEVELOPMENT SEQUENCEA = Fir

Page 4 - Features and Benefits

12 UV-PRC005-ENModel NumberSide Wall Exhaust/Gravity Damper DIGIT 1-3: UNIT CONFIGURATIONSWE = Side Wall ExhaustSWG = Gravity Relief DamperDIGIT 4: DE

Page 5

UV-PRC005-EN 13GeneralDataTable 1: Energy Recovery Unit Ventilator (ERS)Unit Size Efficiency RangeDimensionsL x W x HWeightwith Skid without SkidE

Page 6

14 UV-PRC005-ENElectrical DataTable E1: ERS-Unit Electrical Data without Electric DefrostTable E2: ERS-Unit Electrical Data with Electric DefrostTable

Page 7

UV-PRC005-EN 15Energy Recovery SystemEach energy recovery unit ventilator has a power relay in the control box controlling the unit through the Trac-e

Page 8

16 UV-PRC005-ENControl WiringERS - With Electric Defrost

Page 9 - Considerations

UV-PRC005-EN 17Control WiringERS - Without Electric Defrost

Page 10 - Shelving

18 UV-PRC005-ENControl WiringSide Wall Exhaust

Page 11

UV-PRC005-EN 19Dimensional DataEnergy Recovery Ventilator

Page 12

©2006 American Standard Inc All rights reserved UV-PRC005-ENUnit Ventilator Accessories from A to ZAs a leader in applied unit ventilator systems, Tr

Page 13 - UV-PRC005-EN 13

20 UV-PRC005-ENDimensional DataWall Box for ERS

Page 14 - Electrical Data

UV-PRC005-EN 21Dimensional DataSide Wall Exhaust

Page 15 - Control Wiring

22 UV-PRC005-ENDimensional DataGravity Relief Damper

Page 16 - ERS - With Electric Defrost

UV-PRC005-EN 23Dimensional DataShelving, Open or Closed

Page 17

24 UV-PRC005-ENDimensional DataShelving with Dynamic Barrier

Page 18 - Side Wall Exhaust

UV-PRC005-EN 25Dimensional DataShelving, Cut-to-Fit Filler

Page 19 - Dimensional Data

26 UV-PRC005-ENDimensional DataPipe Cover

Page 20 - Wall Box for ERS

UV-PRC005-EN 27Dimensional DataWall Box, Horizontal Louver

Page 21

28 UV-PRC005-ENDimensional DataWall Box, Vertical Louver

Page 22 - Gravity Relief Damper

UV-PRC005-EN 29Dimensional DataWall Box, Vertical Louver

Page 23 - Shelving, Open or Closed

UV-PRC005-EN 3Table ofContentsIntroduction 2Features and Benefits 4Application Considerations 9Model Number Description 10Shelving10Energy Recovery Ve

Page 24 - Shelving with Dynamic Barrier

30 UV-PRC005-ENEnergy Recovery VentilatorCabinet: The unit cabinet is a durable, furniture quality steel with exposed edges rounded. Quick acting, key

Page 25 - Shelving, Cut-to-Fit Filler

UV-PRC005-EN 31Shelving and AccessoriesUnit ventilator shelving is manufac-tured from durable cabinet steel and painted in decorator colors as speci-f

Page 26 - Pipe Cover

Trane has a policy of continuous product and data improvement and reserves the right to change design and specifications without notice.Literature Ord

Page 27 - Wall Box, Horizontal Louver

4 UV-PRC005-ENEnergy Recovery Unit VentilatorAir conditioning systems have always had one primary responsibility: deliver sufficient amounts of condit

Page 28 - Wall Box, Vertical Louver

UV-PRC005-EN 5 Air-to-Air Heat ExchangerThe air-to-air heat exchanger is de-signed to support two separate air streams in a counter-flow direction. Th

Page 29

6 UV-PRC005-ENUnit Ventilator ShelvingTrane’s unit ventilator shelving was in-spired by the needs of a classroom set-ting. The design supports applica

Page 30 - Specifications

UV-PRC005-EN 7Side Wall Power ExhaustQuick removal of concentrated air contaminants and building pressuriza-tion are two reasons to include an exhaust

Page 31

8 UV-PRC005-ENWall BoxesWall boxes are to be installed prior to mounting the Classroom Unit Ventila-tor, Side Wall Exhaust, or Energy Re-covery Unit V

Page 32

UV-PRC005-EN 9Energy Recovery Unit Ventilator OperationAn energy recovery ventilator can help make mechanical ventilation more cost effective by trans

Comments to this Manuals