Trane Gas Unit Heaters Installation Manual Page 33

  • Download
  • Add to my manuals
  • Print
  • Page
    / 43
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 32
Maintenance
GKND-SVX01B-EN 33
12. Check lubrication instructions on the motor. If oiling is
required, add 3 to 4 drops of electric motor oil as
follows:
a. Light Duty—After 3 years or 25,000 hours of
operatio
n.
b. Average Duty—Annually after 3 years or
8,000 hours of operation.
c. Heavy Duty—Annually after 1 year or at least every
1,500 hours of operation.
13. Check and test the operational functions of all
safety
devices supplied with your unit.
NOTICE:
Equipment Damage!
Never over oil the motor or premature failure could
occur!
Page view 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 ... 42 43

Comments to this Manuals

No comments