Trane VUV 750 CFM User Manual

Browse online or download User Manual for Fans Trane VUV 750 CFM. Trane VUV 750 CFM User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
UV-SVN03D-ENOctober 2007
Models
A” and later Design Sequence
Installation
Owner
Maintenance
Vertical Unit Ventilator
Classroom Unit Ventilator
Model VUV
VUVE
750 CFM
1500 CFM
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - Maintenance

UV-SVN03D-ENOctober 2007Models“A” and later Design SequenceInstallationOwnerMaintenanceVertical Unit VentilatorClassroom Unit Ventilator Model VUVVUVE

Page 2 - Important!

10 UV-SVN03D-ENDimensionsDynamic Air Barrier Unit

Page 3 - Contents

UV-SVN03D-EN 11DimensionsEnd Covers

Page 4 - Pre-installation

12 UV-SVN03D-ENDimensionsWall Boxes

Page 5

UV-SVN03D-EN 13DimensionsCrossover PipingFLUSHFLUSH1 1/2"1 1/4"3"24"19 3/8"3 5/8"5 3/8"RETURN7/8" I.D. FIELDCO

Page 6

14 UV-SVN03D-ENGroutWeepHolesRubberSealsUnitOutsideWallFloorWeepHolesCaulkingOutsideWallInterior Wallw/ sheetrockWater dam slopedtoward exteriorRubber

Page 7 - Clearance

UV-SVN03D-EN 15General Installation ChecksThe checklist below is a summary of the steps required to successfully in-stall a unit. This checklist is in

Page 8 - Standard Depth Unit

16 UV-SVN03D-ENABCDEFCB InstallationFigure 3: Mounting hole locationABCDE F075Standard Unit (no Falseback) 1.31 13.50 2.75 66.39 10.38 45.64Standard f

Page 9 - Falseback Unit

UV-SVN03D-EN 17Unit MountingNote: All wall intake boxes should be installed prior to mounting the unit ventilator. Refer to Page 14 for wall box insta

Page 10 - Dynamic Air Barrier Unit

18 UV-SVN03D-ENPiping Installation Before installation of piping package, the shipping bracket holding the pip-ing in place, must be removed. Proper i

Page 11 - End Covers

UV-SVN03D-EN 19Split System Units The following refrigerant piping and interconnecting wiring instructions apply to unit ventilators with direct ex-pa

Page 12 - Wall Boxes

© 2007 American Standard All rights reserved. UV-SVN03D-ENNoticeNOTICE:Warnings and Cautions appear at appropriate sections throughout this manual. R

Page 13 - Crossover Piping

20 UV-SVN03D-ENModulating Water Valves (Option) The actuator on the valve is a 24V, 3-point floating valve. The actuator can be easily removed from th

Page 14

UV-SVN03D-EN 21Manually Opening ValveThe manual opener can be manipulat-ed only when in the up position. The A port can be manually opened by firmly p

Page 15

22 UV-SVN03D-ENSoldering procedures are as follows:1 Remove actuator as stated earlier. 2 Place valves on the pipe. Rotate valve stem so the shaft sl

Page 16

UV-SVN03D-EN 23WARNINGHazardous Voltage!Disconnect all electric power, in-cluding remote disconnects be-fore servicing. Follow proper lockout/tagout p

Page 17

24 UV-SVN03D-ENElectricalRequirementsTable E1: VUV 075-150, Electrical Performance Blower Blower Number of Electric Electric Minimum Overcurrent Unit

Page 18

UV-SVN03D-EN 25ElectricalRequirementsTable E1: VUV 075-150, Electrical Performance (continued) Blower Blower Number of Electric Electric Minimum Over

Page 19

26 UV-SVN03D-ENPre-StartChecklistPre-Start-up ChecklistBefore energizing the unit, the following system devices must be checked:____ Is the high volt

Page 20

UV-SVN03D-EN 27WARNINGHazardous Service Procedures!The maintenance and trouble-shooting procedures recommend-ed in this section of the manual could re

Page 21

28 UV-SVN03D-ENWARNINGHazardous Service Procedures!The maintenance and trouble-shooting procedures recommend-ed in this section of the manual could re

Page 22

UV-SVN03D-EN 29WARNINGHazardous Service Procedures!The maintenance and trouble-shooting procedures recommend-ed in this section of the manual could re

Page 23

UV-SVN03D-EN 3ContentsInstallation/Startup/Commissioning4Pre-installation Checklist4General Information5Dimensions/Weights7Installation Instructions14

Page 24 - Electrical

30 UV-SVN03D-ENWarranty InformationStandard WarrantyThe standard unit ventilator warranty is Trane’s parts-only warranty, running 12-months from start

Page 25

UV-SVN03D-EN 31Trouble Shooting ChecklistWARNINGHazardous Service Procedures!The maintenance and trouble shooting procedures recommended in this secti

Page 26 - Checklist

32 UV-SVN03D-ENTrouble Shooting ChecklistProblem Heating Cooling Cause CorrectionRoom too coolX Room sensor is not properly set Reset room sensor temp

Page 27

UV-SVN03D-EN 33Unit WiringField Installed Wiring120V/1 PH - 3-Speed

Page 28

34 UV-SVN03D-ENUnit WiringEnd Device Controls120V/1 PH - 3-Speed, DX/Hot Water

Page 29

UV-SVN03D-EN 35Unit WiringEnd Device Package480V/3 PH - 3-Speed, Chilled Water/Electric Heat (6-Element) -page 1

Page 30 - Information

36 UV-SVN03D-ENUnit WiringEnd Device Package480V/3 PH - 3-Speed, Chilled Water/Electric Heat (6-Element) -page 2

Page 31 - Trouble Shooting

UV-SVN03D-EN 37Unit WiringEnd Device Package120V/1 PH - 3-Speed, 4-Pipe Hot Water/Chilled Water

Page 32

38 UV-SVN03D-ENUnit WiringTracer ZN520120V/1 PH - 3-Speed, 4-Pipe Hot Water/Chilled Water

Page 34 - End Device Controls

4 UV-SVN03D-ENJobsite Inspection Always perform the following checks before accepting a unit:1. Verify that the nameplate data matches the data on the

Page 35 - End Device Package

Trane has a policy of continuous product and data improvement and reserves the right to change design and specifications without notice.Literature Or

Page 36

UV-SVN03D-EN 5Unit NameplateThe unit nameplate is located in the left hand end pocket, behind the con-trol box. It includes the unit model number, ser

Page 37

6 UV-SVN03D-ENOA/RA Actuator (Option)The OA/RA actuator provides true spring return operation for positive close-off of the OA/RA damper. The spring r

Page 38 - Tracer ZN520

UV-SVN03D-EN 7Table G1: VUVE general dataUnit Location and ClearancesLocate the unit in an indoor area. The ambient temperature surrounding the unit m

Page 39 - UV-SVN03D-EN 39

8 UV-SVN03D-ENDimensionsStandard Depth Unit

Page 40

UV-SVN03D-EN 9DimensionsFalseback Unit

Comments to this Manuals