Trane 120R9V User Manual

Browse online or download User Manual for Water heaters & boilers Trane 120R9V. Trane 120R9V User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Upflow/Horizontal
Two-stage Condensing
Gas-Fired Furnace
XV 90
TUY060,080,100,120R9V
Variable Speed Blower
Variable Speed Inducer
PUB. NO. 22-1682-05-0802 (EN)
TDD-D-1
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - Gas-Fired Furnace

Upflow/HorizontalTwo-stage CondensingGas-Fired FurnaceXV 90TUY060,080,100,120R9VVariable Speed BlowerVariable Speed InducerPUB. NO. 22-1682-05-0802 (E

Page 2 - Features

10 Pub. No. 22-1682-05-0802 (EN)PerformanceDataTUY120R9V5V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTEROUT

Page 3 - Contents

11Pub. No. 22-1682-05-0802 (EN)SCHEMATIC DIAGRAMS FOR GAS FURNACESTUY060,080,100,120R9V-VLEGENDElectricalDataFrom Dwg. 21D341111 P03

Page 4

12 Pub. No. 22-1682-05-0802 (EN)TO 115 V 1 PH.,60 HZ., POWERSUPPLY PERLOCAL CODESHUM SEENOTE 5EAC SEENOTE 5FieldWiringFIELD WIRING DIAGRAM FOR SINGLE

Page 5

13Pub. No. 22-1682-05-0802 (EN)FieldWiringFIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)From Dwg. 21B34112

Page 6

14 Pub. No. 22-1682-05-0802 (EN)FieldWiringFIELD WIRING DIAGRAM FOR 2 STAGE HEATING TWO STAGE COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)From Dwg. 21

Page 7

15Pub. No. 22-1682-05-0802 (EN)DimensionsTUY-R9V-V OUTLINE DRAWING(ALL DIMENSIONS ARE IN INCHES)

Page 8

Since Trane has a policy of continuous product improvement, it reserves the right to change design andspecifications without notice.TraneA business of

Page 9

2 Pub. No. 22-1682-05-0802 (EN)GeneralFeatures© 2002 American Standard Inc. All Rights ReservedNATURAL GAS MODELSCentral heating furnace designs arece

Page 10 - Performance

3Pub. No. 22-1682-05-0802 (EN)ContentsFeature SummaryFeatures and BenefitsStandard EquipmentOptional EquipmentGeneral DataTUY060R9V3VTUY080R9V3VTUY100

Page 11 - Electrical

4 Pub. No. 22-1682-05-0802 (EN)XV 90 STANDARD EQUIPMENTFeaturesand Benefits• Variable speed indoor blower• Silicon Nitride Igniter with adaptiveheat u

Page 12 - From Dwg. 21B341126 Rev. 0

5Pub. No. 22-1682-05-0802 (EN)Featuresand BenefitsOPTIONAL EQUIPMENTThermostat, Mechanical 2-Stage Heating/1-Stage Cooling ...

Page 13 - From Dwg. 21B341125 Rev. 1

6 Pub. No. 22-1682-05-0802 (EN)TUY-R9V PRODUCT SPECIFICATIONS1MODELRATINGS21st Stage Input BTUH1st Stage Capacity BTUH (ICS)32nd Stage Input BTUH2nd S

Page 14 - From Dwg. 21B341128 Rev. 0

7Pub. No. 22-1682-05-0802 (EN)PerformanceData*UY060R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTEROUTDO

Page 15 - Dimensions

8 Pub. No. 22-1682-05-0802 (EN)PerformanceDataTUY080R9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTEROUTD

Page 16 - Supersedes TDD-D-1 8/95

9Pub. No. 22-1682-05-0802 (EN)PerformanceDataTUY100R9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTEROUTDO

Comments to this Manuals